Continuous Wave EM add on for GE /Tensor mud pulse systems

Typical uses for EM:

Features:

CW EM specifications:

Transmission mode 

Continuous wave

Retrievable 

Yes, standard restrictions apply

Operating depth without repeater  (typical)

4000m (10,000 feet)

Data rate

2 BPS

Maximum output power

10 watts

Downlink  

Pump controlled, frequency and power adjustable.

Operating temperature

150 degrees C (302 F)

Operating pressure  (maximum)

20,000 PSI

Shock (maximum) 

1,000G

Vibration (maximum)

30-500Hz 20 G (all axis’)